500Hz wholesaler Brushless Motor Drive Controller Manual Protection 30 Speed 180rpm 2500rpm 3 Pole 143*80*33 24V 48V 60vdriver for BLDC with ce certificate top quality low price

Product Description

 

BL2415
Name NOTE
DC+/DC- DC voltage input (DC 24V~DC 84V)
U,V,W Motor Phase Line
Hu,Hv,Hw Hall signal
VCC Hall CZPT +
SV External speed regulation. suspended when using internal speed regulation.
F/R Direction, suspended or high at normal times positive turn, low level reverse.
EN Control signal enable high level stop, low level run
BRK Brake, low CZPT normally for normal operation, high level shutdown
ALARM Alarm signal output

 

Electrical Specifications
Projects Minimum value Typical values Maximum value
Input voltage 24 48 60
Output current 6

35

Apply CZPT CZPT (rpm)

20000

Hall Signal Voltage (V)

4.5 5 5.5

Hall CZPT Current (mA)

20

External governor (KΩ)

10
Over-current protection function Overcurrent protection occurs when the current exceeds the operating current setting value and lasts a set time
Overpressure An overvoltage protection occurs when the voltage exceeds 30 V
undervoltage undervoltage protection when voltage is below 10 V
Hall anomaly Hall signal anomaly
We can also CZPT ize products according to CZPT er requirements.

 

Name Note

DC+/DC

DC voltage input (DC 10V~DC 24V)

U,V,W

Motor Phase Line

Hu,Hv,Hw

Hall signal

VCC

Hall CZPT +

SV

External speed regulation. suspended when using internal speed regulation

F/R

Direction, suspended or high at normal times positive turn, low level reverse

EN

Control signal enable high level stop, low level run

BRK

Brake, low CZPT normally for normal operation, high level shutdown

ALARM

Alarm signal output

 

Signal

Termina

Content

Power
supply
Input

DC+

DC CZPT input positive. (Voltage range DC24~60 V)

DC-

DC CZPT input negative electrode

Motor

Hall

W

DC brushless motor W phase.

V

DC brushless motor V phase.

U

DC brushless motor U phase.

Signal

Connection

REF-

dc brushless motor hall signal ground wire.

HW

Hall Signal HW. for DC Brushless CZPT

HV

Hall Signal HV. for DC Brushless CZPT

HU Hall Signal HU. for DC Brushless CZPT

REF+

dc brushless motor hall signal CZPT cord.

Control

Signal

SV

1 external speed regulating potentiometer ;2 external analog signal speed

regulating input ;3 PWM speed regulating signal input.

COM

common port (0 V reference level).

F/R

When the F/R end is disconnected from the COM end or when the high level input is

EN

The motor stops slowly when the EN and COM ends are disconnected or high level input, and the motor runs when short connection or low level input.

BRK

BRK end and COM end disconnect or high level input timing brake stop, short

connection or low level input when motor running.

Output

signal

SPEED

corresponding to the running speed of the motor and output the corresponding pulse The formula is:
N(rm)=(F/P)x60/3
F:output pulse frequency;Hz:P: motor pole logarithm:N: motor speed
2ms
Example:Motor 4 poles F=sec/2msF=500Hz
N(rm)=(500/4)x60/3=2500

ALM

Motor or drive control fault signal output signal, normal 5 V, when failure level

is 0 V..

 

Alarm  indication

State description

Countermeasures

Red light flashes 2 times

Overpressure alarm

alarmCheck voltage

Red light flashes 3 times

Overflow CZPT for CZPT Tube

Determine whether the selection is correct

Red light flashes 4 times

Over-current alarm

Check P-sv setting, proofread motor parameters. or increase the acceleration time.

Red light flashes 5 times

undervoltage alarm

Check the supply voltage and check whether the supply CZPT meets the condition of 1.5 times greater than the motor CZPT

Red light flashes 6 times

Hall alarm

Please check to see if the motor wiring is secure.

Red light
flashes 7 times

Stopping alarm 

Make sure the motor load is too large

Red light

flashes 8 times

More than two alarms

Hall and shutoff alarm as a common condition. Adjust the P-sv to the maximum when the motor can not speed.

Established in 1994, HangZhou BG CZPT Factory is a professional manufacturer of brushless DC motors, brushed DC motors, planetary gear motors, CZPT motors, CZPT motors and AC motors. We have a plant area of 6000 square meters, multiple patent certificates, and we have the independent design and development capabilities and strong technical force, with an annual output of more than 1 million units. Since the beginning of its establishment, BG motor has focused on the overall solution of motors. We manufacture and design motors, provide professional CZPT ized services, respond quickly to CZPT er needs, and actively help CZPT ers to solve problems. Our motor products are exported to 20 countries, including the CZPT States, Germany, CZPT , the CZPT CZPT dom, Poland, Slovenia, Switzerland, Sweden, Singapore, South Korea etc.
Our founder, Mr. CZPT , has more than 40 years of experience in motor technology, and CZPT other engineers also have more than 15 years of experience, and 60% of CZPT staff have more than 10 years of experience, and we can assure you that the quality of CZPT motors is top notch.
The products cover AGV, underwater robots, robots, sewing machine industry, automobiles, medical equipment, automatic doors, lifting equipment, industrial equipment and have a wide range of applications.
We strive for excellence in the quality of each product, and we are only a small and sophisticated manufacturer.
Our vision: CZPT the world forward and make life better!

 

1. How can I use the driver for the first time?
A: After correctly connecting the CZPT line, motor line, and Hall line, the external potentiometer slowly accelerates, and the motor rotates correctly, and then test the enable, direction and other functions in turn. If you are unfamiliar with this product, you should test it for the first time before installing it for actual use.

2. What is the impact of reverse CZPT connection?
A: Will burn the drive immediately.

3. What is the highest voltage of the upper control signal V?
A: The maximum voltage of the speed control signal is 5V, exceeding this voltage will cause the drive to burn.

4. After the driver has been working for a CZPT time, the housing is relatively hot, is it normal?

A: Normally, under normal temperature, working the shell for a CZPT time to 90 degrees will not affect the performance.

5. The CZPT indicator is on, but the motor does not rotate and shakes. What is the reason?
A:It may be that there is an error between the phase line and the Hall line. Please follow the motor manual and reconnect the CZPT to test.

6. Can I adjust the speed of my motor to 6000 with this driver?
A:The maximum speed of the brushless motor is determined by the parameters of the motor itself, and the driver can control the motor speed from 0 to the highest speed.

7. I already have a motor on my hand. How do I connect it after purchasing this driver?
A:You must first determine the definition of the phase line and Hall line of the motor on your hand before wiring. If you are not sure, you need to ask the motor manufacturer. Incorrect wiring will cause damage to the drive.

8. Can I add some functions to this drive or develop new products?
A: Yes, please contact CZPT company.